INSTALLATION
- Inspect the site for installation.
- The modules can operate up to 1/2" air gap; maintain close center-to-center alignment between the sensor and target magnet (see orientation note).
- MAGNASPHERE concealed sensors may be installed directly into steel doors and frames.
- For the MSS-19C, drill .75" dia. x 1.125" deep holes for both the sensor and magnet modules.
- For the MSS–25C, drill 1" dia. x 1.25" deep holes for both the sensor and magnet modules.
- Connect the leads to the system.
- Secure both modules by coating the diameter and flange with RTV compound and inserting them into the drilled holes.
- ORIENTATION NOTE
- Modules are sensitive in one direction. The set should be installed with center-to-center alignment within 3/16”.
-
- >>